SWE Rapid High Resolution Running Buffer

คุณสมบัติสินค้า:

SKU :

Quantity

แบรนด์ : Servicebio

Share

Product Information

Product Name

Cat. No.

Spec.

SWE Rapid High Resolution Running Buffer (Powder)

G2081-1L

1 L

G2081-15

1 L, 15 bags


Product Description/Introduction

The SWE Rapid High Resolution Running Bufferr (powder) is optimal to Tris-Glycine electrophoresis buffer for SDS-PAGE gel electrophoresis in Tris-Glycine. Compared with the traditional Tris-glycine running buffer, this product can be used for electrophoresis without adjusting the voltage according to the separation gel and the stacking gel, and it can be used for the whole process of electrophoresis at a constant voltage of 200-250 V. It takes about 30 min to complete the electrophoresis, which saves time and is more effective for the separation of small molecules. It can separate the 10 kDa and the 15 kDa bands in the prestained protein marker and clearly visible (gel concentration above 8%) to achieve rapid and efficient isolation of 

proteins.


Storage and Shipping Conditions

Ship and store at room temperature. Valid for 24 months.


Assay Protocol/Procedures

1. Each bag of electrophoresis buffer (powder) is dissolved in 1000 mL of purified water, and can be used after fully dissolved.

2. Selection of different protein gel concentrations for different protein molecular weights, refer to the table below:

SDS-PAGE Separation Gel Concentration

Optimum Separation Range (kDa)

(SWE Rapid High Resolution Running Buffer)

6%

15-300

8%

10-250

10%

5-150

12%

3-100

15%

<60

3. Constant voltage electrophoresis, 200-250 V, Refer to the following table for electrophoresis time:

Comparison Table of Electrophoresis Voltage and Electrophoresis Time

Voltage(V)

Estimated Electrophoresis Time(min)

200

35

220

30

250

25


Note

4. It is recommended to use the working solution as soon as possible after preparation.

5. This product is suitable for conventional Tris-HCl system SDS-PAGE gels, such as our products  G2003, G2037, G2041, G2042,G2043,G2044,G2045,G2060,G2061,G2062, G2063,G2064.

6. High voltage electrophoresis is easy to produce high heat. Please select the appropriate voltage for electrophoresis according to the ambient temperature.

7. The running solution can be reused for 2-3 times, more reuse is not recommended.

8. For your safty and health, please wear safety glasses, gloves, or protective clothing.

 

For Research Use Only!

https://www.servicebio.com/goodsdetail?id=29852

เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว  และ  นโยบายคุกกี้