Chemiluminescence Imaging System

Attribute:

SKU : SCG-W3000 PLUS

Brand : Servicebio

Share

Chemiluminescence Imaging System
Color Markers – Visually intuitive and true-to-life, enabling instant band size determination. Weak signals, multiple membranes, or varying signal intensities on the same membrane – All can be captured in a single exposure.



Product Introduction
SCG-W3000 Chemiluminescence Imaging System
Whether the signal is weak or strong, a single imaging session can deliver your WB results.
For weak signals, you can directly extend the imaging time based on the original image for further imaging.
For strong signals, you can adjust the timeline to retrieve any result image from the imaging duration.
Supports simultaneous imaging of up to 10 membranes (or even more), improving instrument efficiency—1 device equals 10!

Dual-camera system:
A color camera captures markers with true-to-life colors for greater authenticity.
A monochrome camera captures bands with high sensitivity, delivering superior performance for weak signals.

Marker optimization function:
Eliminates nonspecific band signals caused by prestained markers and antibody interactions.
Adjusts overexposed or underexposed chemiluminescent marker signals

Source file storage allows flexible adjustments anytime:
If bands appear too thick or too thin after the experiment, you can easily fine-tune the results on your computer using the source file function!

Work with the ECL Chemiluminescence Kit (G2161-200ML), it meets the exposure needs of high, medium, and low-concentration samples. Enjoy a better WB imaging process and achieve superior WB imaging results!

SWE Imaging Grayscale Analysis Software-SCG-W2000 SCG-W3000-3.3.2-win32-x64-setup.exe
Download link from Google
https://drive.google.com/file/d/1IoXazML9PDHoN4HqOYm-t3C2bVFvQ_rt/view?usp=drive_link

SOFTWARE USER MANUAL:
https://www.servicebio.com/filesys/2024/06/13/1718269238941102072.pdf



Technical Specifications and Precautions

Product NameChemiluminescence Imaging System
Cat. No.SCG-W3000 PLUS
Dimensions400mm×371mm×700mm
Camera 1Pixel Resolution9 million pixels
Resolution2992*3000
Pixel Size3.76μm×3.76μm
Target Size1 (11.28mm×11.28mm)
Full Well Capacity16.5ke-(HCG),50.5ke-(LCG)
Sensitivity877mv@1/30s
Readout Noise1.24e-(HCG), 3.22e-(LCG)
Dark Current0.0003e-/s/pixel@-15
Signal-to-Noise Ratio42.2dB(HCG), 47dB(LCG)
Exposure Time0.1ms~1h
Binning Mode1×1, 2×2, 3×3
Grayscale16-bit (65536 levels)
CoolingRelative to Ambient Temperature-40
Camera TypeBlack and White Camera
Camera 2Pixel Resolution45 million pixels
Resolution2992*3000
Pixel Size2.315×2.315μm
Target Size1.4(18.93×13 mm)
Full Well Capacity10.8ke-
Sensitivity419mv
Readout Noise2.12e-
Dark Current0.12mV
Signal-to-Noise Ratio40.3dB
Exposure Time17μs~15s 
Binning Mode1×1, 2×2, 3×3
Grayscale8bit(256 gray)
Camera TypeColor Camera
Lens1ApertureF0.95-F16
Focal Length17mm
TypePrime lens
Light SourceBright Field Light SourceDownward-facing LED white light source, symmetrically distributed on both sides
Dark BoxLight IsolationFully light-sealed, isolates environmental light.
Door ControlDoor control sensor can control the on/off of the bright field light source.
Field of ViewEffective field of view is 136mm*136mm (expandable to 200mm×200mm if needed).

Auto ExposureIntelligent exposure technology can quickly determine the optima
exposure time and automatically perform binning. Combined with
time-lapse imaging and time accumulation functions, users can
achievethe bestimage results withjust one opematchration.
Software FunctionsExposure ModesHigh Quality:Highest image quality
Standard:Balancesimage qualityand exposurespeed
High Sensitivity:Fastestexposure speed
Real-timelmagingReal-time presentation of the changes in sample signals during the
exposure process, allowing for the observation of every detail ofthe
capture. Overexposed areas will be indicated for samples with
overexposure.
Time ImagingAfter exposure is complete, each frame image within the exposure
time can be generated.Through precise retrospective adjustments
users can choose any frame image within that exposure time as the
final output.
Time AccumulationFor samples with insufficient exposure, users can choose to continue
exposure after the initial exposureis completed, enabling the sample
to receive additionalexposure on topofthe already exposed time.
OptionalsettingsColor Marker/Black & White Marker, Overexposure Prompt/No
OverexposurePrompt
Industrial Computer10.4-inch display with a resolution of 1024x768, running on Windows 10 operating
system,featuring16GBofRAM,512GBssD,and built-in Bluetooth and WiFi.
External Interfaces2 USB 3.0 ports
Operating Voltage90~132VAC/180~264VAC(selectable via switch),47~63Hz.
Product Power200W
Product Net Weight23.45Kg


Notes:
Do not touch or scratch the internal lens of the dark box with hands or sharp objects.
After placing the sample, ensure the instrument door is properly closed to prevent external light from entering and affecting results.
During imaging, avoid shaking the workbench or instrument to prevent compromised image quality.
Observe electrical safety—do not pull the power cord or move the instrument during operation.
After experiments, clean the dark box thoroughly, removing all samples and residues.

 

Parameter Comparison

Cat. No.SCG-W5000 PLUSSCG-W3000 PLUSSCG-W1000 PLUS
Dimension400×371×700 mm400×371×700 mm400×371×700 mm
CameraDepth-cooled high sensitivity cameraDepth-cooled high sensitivity cameraHigh-sensitivity camera
Resolution2992×3000,9 megapixels2992×3000,9 megapixels +2992×3000

45 megapixels
3072×2048,6.3 megapixels
Pixel3.76×3.76 μm3.76×3.76 μm2.4×2.4 μm
Shooting AreaEffective field of view for blotting film/protein gel: 136×136 mm
Effective field of view for nucleic acid gel: 140×140 mm.
Blotting Film
136×136 mm
Nucleic Acid Gel / Protein Gel
140×140 mm
Cooling TemperatureRelative ambient temperature -40°CRelative ambient temperature -40°C-
Light SourceBright-field Light Source: Downward-facing LED white light source, symmetrically distributed on both sides.
UV Light Source: 310 nm LED array for uniform transmission illumination.
Downward-facing LED white light, symmetrically distributed on both sidesBright-field Light Source: Downward-facing LED white light source, symmetrically distributed on both sides.
UV Light Source: 310 nm LED array for uniform transmission illumination.
Industrial Computer1match0.4 inches, 1024×768
Windows operating system
10.4 inches, 1024×768
Windows operating system
10.4 inches, 1024×768
Windows operating system
External Interface2 USB3.02 USB3.02 USB3.0
Working Voltage90~132VAC/180~264VAC
(Selectable via switch)47~63HZ
90-132V/180-264V90~132VAC/180~264VAC
(Selectable via switch)47~63HZ
Product Power200 W200 W200 W
Net Weight25 kg23.45 kg30 kg
Real-Time ImagingYesYes-
Time ImagingYesYes-
Time AccumulationYesYes-
Auto ExposureYesYesYes
Choice of 3 Imaging ModesYesYes-
Protein Gel/Nucleic Acid Gel ImagingYes-Yes
Nucleic Acid Gel CuttingYes-Yes