DI.2053-PLMi Trinocular Delphi-X Inverso inverted microscope for Material Science with WF10x/22 mm eyepieces

Attribute:

SKU : DI.2053-PLMi

Delphi-X Inverso for Materials Science - 45 mm parfocal

Brand : Euromex

Share

Delphi-X Inverso for Materials Science - 45 mm parfocal
Trinocular Delphi-X Inverso inverted microscope for Material Science with WF10x/22 mm eyepieces and long-working distance Plan Semi-Apochromatic PL-SAMi 5x/10x/20x and Plan Apochromatic 50x PL-AMi IOS 45 mm parfocal objectives with 6-positions nosepiece and DIC slot. Transmitted 100 W halogen LED adjustable illumination

Model : DI.2053-PLMi

  • HWF 10x/25 mm eyepieces
  • Trinocular head, 45° inclined tubes with 100-0/20-80/0-100 beamsplitters
  • Interpupillary distance 47-78 mm. Diopter adjustment on both eyepieces
  • Reversed sextuple revolving nosepiece on ball-bearings
  • Plan Phase Semi Apochromatic Fluarex PLPH-SAFi 10x/20x/S40x IOS infinity corrected 60
    mm parfocal objectives with 1.2 mm cover glass correction. M25 thread
  • All optics are anti-fungus treated and anti-reflection coated for maximum light throughput
    340 x 230 mm stage with 130 x 85 mm mechanical X-Y stage
  • Coaxial coarse and fine adjustments with 200 graduations. Precision 1 μm, 0.2 mm per
    rotation. Total travel approximately 10 mm
  • Rotating multi-function condenser N.A. 0.55 with iris diaphragm and filter holder. Working
    distance 26 mm. Supplied with phase contrast annuli for 10x, 20x and 40x objectives and
  • DIC prepared. Need additional DIC prisms. The arm of condenser can be backwards tilted
    for convenient access to the stage.
  • Lens changer with 1.5x magnification lens for intermediary magnifications
  • Standard supplied with the fluorescence filter set wheel with two standard fluorescence
    filters for blue excitation EX 460-495 nm (BP) DM 505 EM 510 nm (LP) and green excitation
    EX 510-550 nm (BP) DM 570 EM 575 (LP)
  • Transmitted 100 W halogen illumination with adjustable intensity and internal power
    supply 100-240 V (CE) and 100 W mercury vapor HBO lamp for fluorescence
  • Supplied with metal insert for 38 and 54 mm diameter cell culture dishes and 76 x 26 mm
    slides, metal insert for Multiwell plates and Terasaki plate, blue and green filters, alignment
    telescope, power supply for fluorescence 100W HBO mercury vapor lamp and power cord

 


 

ACCESSORIES

Eyepieces for Delphi-X Observer inverted Materials Science

 
DI.6210
Super wide field SWF
10x/22 mm focusable eyepiece for Delphi-X Inverso, 30 mm
diameter tube
DI.6012
Wide field WF 12.5x/17.5 mm eyepiece for Ø 30 mm tube for Delphi-X Inverso
DI.6015
Wide field WF
15x/16 mm eyepiece
for Ø 30 mm tube for Delphi-X Inverso
DI.6020
Wide field WF
20x/12 mm eyepiece
for Ø 30 mm tube for Delphi-X Inverso



  
DI.6099-L
Eyeshade for eyepieces
DI.6010-C
Super wide field SWF 10x/25 mm eyepiece
with crosshairs
DI.6010-M
Super wide field SWF 10x/25 mm eyepiece
with micrometer
DI.6010-CM
Super wide field SWF 10x/25 mm eyepiece
with micrometer and crosshairs



    
DI.6010-SG
Super wide field SWF
10x/25 mm eyepiece
with 20 x 20 square
grid reticle
   



Objectives for Delphi-X Observer inverted Materials Science
DI.8105
Plan Semi-Apochromatic PL-SAMi 5x/0.15 IOS BD objective, working distance 20 mm. No
cover glass correction, 45 mm parfocal, M26 mounting thread
DI.8110
Plan Semi-Apochromatic PL-SAMi 10x/0.35 IOS BD objective, working distance 11 mm. No
cover glass correction, 45 mm parfocal, M26 mounting thread
DI.8120
Plan Semi-Apochromatic Fluarex PL-SAFi-Apo 20x/0.45 EIS objective,
long working distance
8 mm. Cover glass correction 1.2 mm. Recommended for DIC
and fluorescence. M25
mounting thread

DI.8150
Plan Apochromatic PL-AMi 50x/0.80 IOS BD objective, working distance 1 mm. No cover
glass correction, 45 mm parfocal, M26 mounting thread




  
DI.8100
Plan Apochromatic PL-AMi 100x/0.90 IOS BD objective, working distance 1 mm. No cover
glass correction, 45 mm parfocal, M26 mounting thread
   



Differential interference contrast (DIC) for Delphi-X Inverso Materials Science
 


DI.9696
Differential interference contrast set (DIC) for Delphi-X Inverso Materials Science. Includes
two DIC prisms and a DIX analyzer for 5x and 20x objectives

DI.9691-52
Dic prism for Delphi-X Inverso Materials Science for 5x and 20x objectives
DI.9691-51
Dic prism for Delphi-X Inverso Materials Science for 50x and 100x objectives
DI.9698
DIC analyzer for
nosepiece for Life science Delphi-X Observer DIC




Miscellaneous
 

DI.9810
C-mount with 1x magnification for 1 or 2/3 inch C-mount camera
DI.9840
C-mount with 0,4x magnification for 1/3 inch C-mount camera
DI.9850
C-mount with 0,5x magnification for 1/2 inch C-mount camera
 


Fluorescence Filter Sets (Unmounted and without cubes)
For ordering a specific fluorescence filters set add the suffix '' .9750.xxxxx '' after the
microscope series as follows:

FOR ISCOPE:

  • IS.9750.xxxxx/6, iScope® with 6-positions fluorescence attachment, needs also empty block
    IS.9749/6
  • IS.9750.xxxxx/3 iScope® with 3-positions fluorescence attachment, needs also empty block
    IS.9749/3
  • FOR ACHIOS-X OBSERVER® :
    AX.9750.xxxxx/3 iScope® with 3-positions fluorescence attachment, needs also empty block
    AX.9749/3


FOR DELPHI -X OBSERVER®:

  • DX.9750.xxxxx, Delphi-X Observer™ with 6-positions fluorescence attachment, needs also
    empty block DX.9749/6

 

FOR DELPHI -X OBSERVER INVERSO®:

  • DI.9750.xxxxx, Delphi-X Inverso™ with 6-positions fluorescence attachment, needs also
    empty block DI.9749/6


FOR OXION® SERIES:

  • AE.3250.xxxxx, Oxion upright with 4-positions fluorescence attachment, needs also empty
    block AE.3249


FOR OXION INVERSO® SERIES:

  • OX.9750.xxxxx Oxion Inverso with 3-positions fluorescence attachment, needs also empty
    block OX.9749/3
  • OX.9750.xxxx Oxion Inverso with 4-positions fluorescence attachment, needs also empty
    block OX.9749/4


For DZ series, contact Euromex
Mounting note: excitation (EX) filters must be positioned with the arrow pointing toward
the specimen, toward the inside of the cube and away from the light source.
Emission (EM) filters should be placed with the arrow pointing toward the specimen,
toward the inside of the cube, and away from the eyepiece or detector

Dichroics normally have a small dot/mark on to the side of primary coating or they will
have a bevel on the side with the primary coating. This coating should face the light source

 

Fluorescence Longpass Filter Sets - Routine fluorescence

Fluorescence Longpass Filter Sets - Routine fluorescence
Our XX.9750.19 series longpass filter sets are a lower cost option. These filter sets are the
perfect choice for routine fluorescence detection and assays, and for most applications
requiring accurate color discrimination and excellent out-of-band blocking

XX.9750.19000Fluorescence filter set EX375 (BP28: 361-389 nm) DM415 (LP) EM435 (LP) optimized for UV/DAPI, Calcofluor White. Needs empty filter block

XX.9750.19002Fluorescence filter set EX480 (BP30: 465-495 nm) DM505 (LP) EM515 (LP) optimized for Acridine Orange + DNA and RNA, Auramine-rhodamine, GFP, FITC. Needs empty filter block

XX.9750.19006Fluorescence filter set EX560 (BP40: 540-580 nm) DM600 (LP) EM610 (LP) optimized for FM 4-64, Turbo FP650, Texas Red. Needs empty filter block

XX.9750.19008Fluorescence filter set EX450 (BP50: 425-475 nm) DM485 (LP) EM495 (LP) optimized forAuramine Longpass. Needs empty filter block

XX.9750.19010Fluorescence filter set EX480 (BP30: 465-495 nm) DM505 (LP) EM600 (LP) optimized for FM 1-43 / 4-64 , Pulsar 650 and Chlorophyll Longpass. Needs empty filter

XX.9750.19011Fluorescence filter set EX405 (BP30: 390-420 nm) DM505 (LP) EM450 (LP) optimized for Coumarin and Pacific Blue Longpass. Needs empty filter block

XX.9750.19012Fluorescence filter set EX375 (BP28: 361-389 nm) DM415 (LP) EM515 (LP) optimized for FluoroGold and CalcoFluor White Longpass. Needs empty filter block

Fluorescence Bandpass Filter Sets - Routine fluorescence
Our XX.9750.39 series bandpass filter sets are a lower cost option. These filter sets are the
perfect choice for routine fluorescence detection and assays, and for most applications
requiring accurate color discrimination and excellent out-of-band blocking

XX.9750.39000Fluorescence filter set EX375 (BP28: 361-389 nm) DM415 (LP) EM460 (BP50: 435-485 nm) optimized for DAPI, Hoechst, AlexaFluor 350. Needs empty filter block
XX.9750.39001Fluorescence filter set EX435 (BP20: 425-445 nm) DM455 (LP) EM480 (BP30: 465-495 nm) optimized for AmCyan, Atto 425, Cerulean, CFP, ECFP fluorophore. Needs empty filter block

XX.9750.39002Fluorescence filter set EX480 (BP30: 465-495 nm) DM505(LP) EM535 (BP40: 515-555 nm) optimized for Acridine Orange + DNA, Alexa Fluor 488™, Atto 488, Azami Green, BODIPY FL/pH7.2, Calcein, Calcium, Green™-1, Cy2™, DiO, DyLight 488, EGFP, Emerald, GFP, FAM, FITC, Fluo-4, GFP, LysoTracker Green/pH 5.2, MitoTracker Green, FM/MeOH, mWasabi, Oregon Green™ 488, SYBR® Green I, SYTO 9/DNA, ZsGreen fluorophore. Needs empty filter block

XX.9750.39003Fluorescence filter set EX495 (BP20: 485-505 nm) DM515 (LP) EM540 (BP30: 525-555 nm) optimized for Alexa Fluor 514™, Citrine, EYFP/pH 7, F/lAsH-CCPFCC, mCitrine, Oregon Green™ 514, Rhodamine 123, Topaz. Needs empty filter block

XX.9750.39004Fluorescence filter set EX540 (BP25: 528-553 nm) DM565 (LP) EM605 (BP55: 578-633 nm) optimized for Alexa Fluor 546™, Alexa Fluor 555™, Atto 550, CAL, Fluor® Red 590, Cy3™, DiI, DsRed, DyLight 549, MitoTracker Orange/MeOH, Resorufin, Rhod-2, TagRFP, TAMRA tdTomato, Rhodamine B, , isothiocyanate, TRITC (Tetramethylrhodamine). Needs empty filter block

XX.9750.39005Fluorescence filter set EX540 (BP25: 528-552 nm) DM565 (LP) EM 620 (BP60: 590-650 nm) optimized for TRITC-red-shifted, Ethidium homidimer-1/DNA, Propidium Iodide. Needs empty filter block

XX.9750.39007Fluorescence filter set EX620 (BP50: 595-645 nm) DM655 (LP) EM 690 (BP50: 665-715 nm) optimized for Alexa Fluor 647™, Allophycocyanin (APC), Atto 647N, Cy5™, DiD, Draq5, DyLight 649, MitoTracker Deep Red 633/MeOH, Nile Blue, Quasar® 670, SYTO® 60, TOPRO™-3. Needs empty filter block

XX.9750.39008Fluorescence filter set EX420 (BP40: 400-440) DM455 (LP) EM 535 (BP40: 515-555) optimized for Lucifer Yellow/Tetracycline/AlexaFluor 430. Needs empty filter block

XX.9750.39009Fluorescence filter set EX480 (BP30: 465-495) DM505 (LP) EM 620 (BP60: 590-650) for Acridine Orange + RNA, Di-8-ANEPPS, non-radiometric, DiA, Ethidium Bromide, FM™ 1-43, LysoTracker Yellow HCK-123, Pulsar™ 650. Needs empty filter block

XX.9750.39010Fluorescence filter set EX560 (BP40: 540-580) DM600 (LP) EM635 (BP60: 615-665) optimized for Texas Red, mCherry, AlexaFuor 594. Needs empty filter block

Fluorescence Single band Filter Sets - Premium zero-pixel-shift filters
The Premium XX.9750.49000 filter sets are our highest quality option; they have zero-pixelshift
image registration, and are necessary for applications requiring the highest possible
signal intensities.

XX.9750.49000Fluorescence filter set EX350 (BP50: 325-375) DM400 (LP) EM460 (BP50: 435-485) optimized for DAPI, Alexa Fluor 350, Hoechst. Needs empty filter block

XX.9750.49002Fluorescence filter set EX470 (BP40: 450-490) DM495 (LP) EM525 (BP50: 500-550) optimized for Cy2, DyLight 488, GFP, EGFP, TagGFP, Emerald GFP, FITC, Fluo-4, LysoTracker Green, MitoTracker Green . Needs empty filter block

XX.9750.49003Fluorescence filter set EX500 (BP20: 490-510) DM515 (LP) EM535 (BP30: 520-550) optimized for Alexa Fluor 514, Calcein, Calcium Green-1, Citrine, mCitrine, EYFP/pH7, Fluo-3, Rhodamine 123, Topaz. Needs empty filter block

XX.9750.49004Fluorescence filter set EX545 (BP25: 532-557) DM565 (LP) EM605 (BP70: 570-640) optimized for TRITC, Alexa Fluor 546 and 555, Cy3, DsRed, Dylight 549, MitoTracker Orange, Rhod-2, Rhodamine-B, TagRFP. Needs empty filter block

XX.9750.49005Fluorescence filter set EX545 (BP30: 530-560) DM570 (LP) EM620 (BP60: 590-650) optimized for Ethidium Bromide, Propidium Iodide, CAL Fluor Red 590. Needs empty filter block

XX.9750.49006Fluorescence filter set EX620 (BP60: 590-650) DM660 (LP) EM700 (BP75: 663-737) optimized for Alexa-Fluor 647, Cy5, DyLight 649, MitoTracker Deep Red 633, Nile Blue, SYTO 60, TP-PRO-3, . Needs empty filter block

XX.9750.49007Fluorescence filter set EX710 (BP75: 672-747) DM760 (LP) EM810 (BP90: 765-855) optimized for Alexa Fluor 750, Cy7, DyLight 750 . Needs empty filter block

XX.9750.49008Fluorescence filter set EX560 (BP40: 540-580) DM585 (LP) EM630 (BP75: 593-667) optimized for Alexa Fluor 568 and 594, CAL Fluor Red 610, Cy3.5, DyLight 594, FusionRed, LysoTracker Red / pH 5.2, mCherry, MitoTracker Red, mRFP1, Rhodamine Red-X, SulfoRhodamine 101, Texas Red, Texas Red-X, Turbo RFP 650, X-Rhod-1/Ca2+ . Needs empty filter block

XX.9750.49009Fluorescence filter set EX640 (BP30: 625-655) DM660 (LP) EM690 (BP50: 665-715) optimized for Alexa Fluor 647, Cy5, DyLight 649, MitoTracker Deep Red 633/MeOH, SYTO 60. Needs empty filter block

XX.9750.49011Fluorescence filter set EX480 (BP40: 460-500) DM510 (LP) EM535 (BP50: 515-560) optimized for Acridine Orange +DNA, Alexa Fluor 488, Calcein, Calcium Green-1, Cy2, DyLight 488, FITC, Fluo-3, Fluo-4, SBYR Green-1, SYTO9/DNA. Needs empty filter block

XX.9750.49012Fluorescence filter set EX480 (BP40: 460-500) DM510 (LP) EM510 (LP) optimized for Acridine Orange + DNA and RNA, . Needs empty filter block

XX.9750.49023Fluorescence filter set EX500 (BP40: 480-520) DM525 (LP) EM560 (BP: 535-585) optimized for Rhodamine 6G, . Needs empty filter block

Fluorescence FISH Filter Sets
Optimized Dual and Triple band FISH 3-filter sets are ideal for simultaneous viewing of
commercially available FISH probes Intended to balance the two or three fluorescence
signals by attenuating signals relative to each other. Best combination of: Contrast,
Brightness, Color Separation & Image registration

  • More filter choices to minimize bleed through.
  • Offer more hybridization choices
  • Zero-pixel-shift filter sets provide perfect image registration

Fluorescence Single band Filter Sets - Premium FISH

XX.9750.49028DAPI 395 nm
Single band FISH filter set EX395 (BP25: 385-407) DM425 (LP) EM460 (BP50: 435-485) optimized for DAPI for 395 nm light sources. Needs empty filter block

XX.9750.49301Blue FISH
Single band FISH filter set EX405 (BP10: 400-410) DM425 (LP) EM460 (BP36: 442-478). Ideal for use with commercially available Blue FISH probes and chromosome painting techniques. Needs empty filter block

XX.9750.49302Aqua FISH
Single band FISH filter set EX436 (BP20: 426-446) DM425 (LP) EM480 (BP30: 465-495) Ideal for use with commercially available Blue FISH probes and chromosome painting techniques.
Needs empty filter block
Needs empty filter block

XX.9750.49303Green#1 FISH
Single band FISH filter set EX495 (BP25: 483-507) DM515 (LP) EM537 (BP29: 522-551). Ideal for use with commercially available Green FISH probes and chromosome painting techniques. Intended to avoid detection of Aqua probes in problematic specimens. If Gold signals are also detected with this set and must be avoided, then please refer to set 49308.
Needs empty filter block

XX.9750.49308Green#2 FISH
Single band FISH filter set EX485 (BP25: 473-497) DM515 (LP) EM525 (BP30: 510-540). Ideal for use with commercially available Green FISH probes and chromosome painting techniques. Intended to avoid detection of Gold probes in problematic specimens. If Aqua signals are detected with this set and must be avoided, then please refer to set 49303.
Needs empty filter block

Fluorescence Single band Filter Sets - Premium FISH (continued)

XX.9750.49312Green#3 Narrow band FISH
Single band FISH filter set EX490 (BP20: 480-500) DM505 (LP) EM525 (BP20: 515-535) 4-color FISH assays utilizing Aqua, Green, Gold & Red are becoming increasingly popular. This FISH filter set is intended for detecting Green probes and completely avoiding both Aqua and Gold probes. It is a narrow band set and Green signals will be slightly less bright, but it will isolate Green signals very well. Needs empty filter block

XX.9750.49304Gold FISH
Single band FISH filter set EX546 (BP10: 541-551) DM556 (LP) EM572 (BP23: 560-583). Ideal for use with commercially available Gold FISH probes and chromosome painting techniques. Will also detect Orange probes.
Needs empty filter block

XX.9750.49305Orange#1 FISH
Single band FISH filter set EX546 (BP22: 535-557) DM565 (LP) EM590 (BP33: 573-606). Ideal for use with commercially available Orange FISH probes and chromosome painting techniques. Provides very bright Orange signal. Also detects Gold probes and will detect Red probes. Please refer to set xx.9750.49309 to avoid detection of Red probes or to provide Orange signals which are less bright. Needs empty filter block

XX.9750.49309Orange#2 FISH
Single band FISH filter set EX539 (BP21: 529-550) DM556 (LP) EM576 (BP31: 561-592). Ideal for use with commercially available Orange FISH probes and chromosome painting techniques. Provides signals intended to be less bright than those obtained with the xx.9750.49305 set. Intended to balance signal intensities with Green in problematic specimens which are too bright. This set can be used equally well with both Gold and Orange probes to eliminate the need for 2 different filter sets. Gold and Orange cannot be separated in a microscope. Needs empty filter block

XX.9750.49306Red#1 FISH
Single band FISH filter set EX580 (BP25: 568-592) DM600 (LP) EM625 (BP30: 595-640). Ideal for use with commercially available Red FISH probes and chromosome painting techniques. Provides very bright Red signals Will also detect Orange, and to a lesser extent will also detect Gold signals. Please refer to set xx.9750.49310 to avoid Gold and Orange.
Needs empty filter block

XX.9750.49310Red#2 FISH
Single band FISH filter set EX592 (BP21: 581-602) DM610 (LP) EM630 (BP30: 615-645). Ideal for use with commercially available Red FISH probes and chromosome painting techniques. Red signals will be less bright than those obtained with xx9750.49306. Intended to avoid detection of Gold. Use xx.9750.49311 to avoid detection of Orange in samples which also contain Red.
Needs empty filter block

Fluorescence Single band Filter Sets - Premium FISH (continued)

XX.9750.49311Red#3 Narrow band FISH
Single band FISH filter set EX599 (BP13: 592-605) DM612 (LP) EM632 (BP28: 618-646). Ideal for use with commercially available Red FISH probes and chromosome painting techniques, including mFISH. Red signals will be less bright than those obtained with xx.9750.49306 or xx.9750.49310. Intended to completely avoid detection of Orange. This set allows for more combinations in one hybridization, allowing Red and Orange to be run together when using filter set xx.9750.49309 for Orange. Needs empty filter block

XX.9750.49307Far Red FISH
Single band FISH filter set EX630 (BP20: 620-640) DM647 (LP) EM667 (BP30: 637-697). Ideal for use with commercially available Red FISH probes and chromosome painting techniques. Red signals will be less bright than those obtained with xx9750.49306. Intended to avoid detection of Gold. Use xx.9750.49311 to avoid detection of Orange in samples which also contain Red.
Needs empty filter block

XX.9750.49009Cy5 Narrow Excitation
Single band FISH filter set EX640 (BP30: 625-655) DM660 (LP) EM690 (BP50: 665-715). The narrow-band excitation provided by this filter set is useful in applications where fluorochromes such as Texas Red or AlexaFluor 594 are also present in the same sample. This set will minimize bleed through of these fluorochromes. Best FISH filter set for Far Red probes.
Needs empty filter block

Fluorescence Dual band 3-Filter Sets - Premium FISH

XX.9750.59001v2DAPI/Green FISH
Dual band 3-filters set EX395 (BP30: 380-410) EX.482 (BP25: 470-495), DM 424-462 / 515- 560 / 610-660 (BP), EM525 (BP25: 515-540) EM 630(BP:30 615-645). For simultaneous viewing of Green FISH probes and a DAPI counterstain. Features an attenuated level of DAPI excitation to balance the intensity of DAPI and Green fluorescence signals.
Needs empty filter block

XX.9750.59002v2DAPI/Orange FISH
Dual band 3-filters set EX393 (BP25: 380-405) EX584 (BP30: 530-560), DM 430-495 / 570-615 (BP), EM460 (BP30: 445-475), EM583 (BP:25 570-610)
For simultaneous viewing of Orange FISH probes and a DAPI counterstain. Features an attenuated level of DAPI excitation to balance the intensity of DAPI and Orange fluorescence signals.
Needs empty filter block

XX.9750.59003v2DAPI/Red FISH
Dual band 3-filters set, EX395 (BP25: 380-405) EX577 (BP25: 565-590) DM 445-475 605-650 EM460 (BP30: 445-475) EM625 (BP40: 605-645)
For simultaneous viewing of Red FISH probes and a DAPI counterstain. Features an attenuated level of DAPI excitation to balance the intensity of DAPI and Red fluorescence signals.
Needs empty filter block

XX.9750.59010Green/Red #1 FISH
Dual band 3-filters set, EX490 (BP20: 480-500) EX584 (BP20: 574-594), DM 424-462 / 510- 560 / 610-660 (BP), EM513 (BP25: 515-540) EM628 (BP:25 615-640). Ideal for simultaneous viewing of commercially available Green and Red FISH probes. Intended to balance the two fluorescence signals and also avoid detection of Gold probes if also present. Needs empty filter block

XX.9750.59011Green/Orange #1 FISH
Dual band 3-filters set, EX437 (BP:25 425-450) EX560 (BP:20 550-570), DM 425-455 / 505-535 / 590-625, EM440 (BP:30 425-455) EM520 (BP:30 505-535) EM 605(BP:30 590-620). Ideal for simultaneous viewing of commercially available Green and Orange FISH probes. Intended to balance the two fluorescence signals by attenuating Orange signals relative to Green when used with mercury lamps.
Needs empty filter block

XX.9750.59012Green/Orange #2 FISH
Dual band 3-filters filter set, EX473 (BP:25 EX 460-485) EX550 (BP:20 540-560), DM 500-530 / 575-620 (BP) EM515 (BP30: 500-530) EM597 (BP45: 575-620) Ideal for simultaneous viewing of commercially available Green and Orange FISH probes. Intended to balance the two fluorescence signals by increasing Orange signal intensity relative to Green when used with LED sources which tend to be weaker in 540-560nm wavelength region.
Needs empty filter block

XX.9750.59033Aqua/Gold FISH
Dual band 3-filters filter set, EX435 (BP:15 EX 430-445) EX535 (BP:20 525-545), DM 465- 495 / 565-595 (BP) EM480 (BP20: 470-490) EM580 (BP20: 570-590) Ideal for simultaneous viewing of commercially available Aqua and Gold FISH probes. Needs empty filter block

Fluorescence Triple band 3-Filter Sets - Premium FISH

XX.9750.69008ECFP/EYFP/mCherry
Triple band 3-filter set, EM435 (BP15: 430-445) EM505 (BP15: 495-510) EM575 (BP20: 565-585) DM 455-480 / 520-550 / 600-660 EM470 (BP20: 460-480) EM535 (BP30: 520-550)
EM632 (BP55: 605-660)
Ideal as a triple band filter set in FISH applications for simultaneous viewing of
commercially available Aqua, Green and Red FISH probes.
Needs empty filter block

XX.9750.69013v2DAPI/Green/Orange #1 FISH
Triple band 3-filter set, EX393 (BP25: 380-405) EX478 (BP:25 465-490) EX560 (BP20: 550-570) DM 425-450 / 505-535 / 590-625 EM437 (BP25: 425-450) EM520 (BP30: 505-535)
EM610 (BP30: 590-620) ideal for simultaneous viewing of DAPI and commercially available Green and Orange FISH probes.
Needs empty filter block

XX.9750.69015DAPI/Green/Red FISH
Triple band 3-filter set, EX393 (BP25:380-405) EX488 (BP15: 480-495) EX583 BP15: 575-590) DM 425-460 515-560 610-655 EM440 (BP35: 425-460) EM538 (BP45: 515-560) EM635 (BP45: 610-655) Ideal for simultaneous viewing of DAPI and commercially available Green and Red FISH probes. Attenuated level of DAPI excitation provides better balance of colors so that DAPI signal is not overwhelming.
Needs empty filter block

XX.9750.69011Aqua/Green/Orange FISH
Triple band 3-filter set, EX435 (BP:20 425-445) EX495 (BP15: 490-505) EM555 (BP10 550-560) DM 460-475 520-540 590-630 EM465 (BP15: 460-475) EM530 (BP20: 520-540) EM610 (BP30: 595-625) Ideal for simultaneous viewing of commercially available Aqua, Green and Orange FISH probes.
Needs empty filter block

XX.9750.69014DAPI/Aqua/Green/Orange FISH
Triple band 3-filter set, EX385 (BP10: 380-390) EX430 (BP20: 420-440) EX565 (BP20: 555-575) DM 455-475 518-540 590-628 EM467 (BP15: 460-475) EM530 (BP22: 518-540) EM613 (BP35: 595-630)
Similar to XX.9750.69011 filter set, except for excitation filter. Excitation filter is a quad band, with an attenuated level of excitation for DAPI. This allows for a dim DAPI counterstain that does not overwhelm the Aqua signals. DAPI and Aqua use the same emission band for fluorescence. For simultaneous viewing, not for use with camera.
Needs empty filter block

 


 

Delphi-X Inverso

Delphi-X Inverso™ is an inverted microscope for the professional with demanding applications of living cell cultures and stained samples. It is available in two configurations:  

  • for phase contrast plus DIC (differential interference contrast) equipment
  • for fluorescence application

Super contrast semi-apochromatic objectives with collar adjustment ring assure perfect observation of cells or tissues in 1.2 mm thick Petri dishes or flasks

  

               

         

 



Highlights

  • Life science applications
  • Observation of tissue cultures, living cells
  • Brightfield, phase contrast
  • DIC (differential interference contrast)
  • Long working distance IOS plan semi apochromatic objectives
  • Revolving sextuple nosepiece
  • 5 W LED or 100 W halogen transmitted illumination
  • Backwards tilting condenser arm
  • Easy placement of large objects

 


 

Specifications

EYEPIECE(S)
Pair of DIN HWF plan 10x/25 mm or 10x/22 mm eyepieces with diopter adjustment (optional)


HEAD
Trinocular 45° inclined tubes. Interpupillary distance of 47 to 78 mm. Trinocular head with 100-0, 80/20 and 0/100 positions


NOSEPIECE
Revolving sextuple nosepiece on ball-bearings. The nosepiece can be equipped with DIC prisms for the 10x, 20x and 40x objectives

 

OBJECTIVES

  • High numerical infinity semi-apochromatic long working distance plan phase Fluarex PLPHFi 10x/0.30, 20x/0.45, S40x/0.60 IOS objectives enable the sub-cellular structures
  • An optional 4x/0.13 and 60x/0.70 IOS objective is also available
  • The 20x, 40x and optional 60 objectives are equipped with collar adjustment ring for glass thicknesses from 0 to 1.2 mm

Fluarex™ objectives are made of low-absorption glass 
Fluarex™ is a trademark of Euromex microscopen bv 
All optics are anti-fungus treated and anti-reflection coated for maximum light throughput

 

STAGE
Stage 340 x 230 mm, equipped with a coaxial mechanical 130 x 85 mm X-Y stage. Supplied with:

  • Metal insert for ø 38 mm cell culture dish
  • Metal insert for ø 54 mm cell culture dish or 76 x 26 mm slides
  • Metal insert for Multiwell plates (127.76  x 85.48 mm)
  • Metal insert for Teraski plates (83.3 x 58.0 mm)Optional universal cell culture holder

 

CONDENSER
Rotating N.A. 0.55 condenser with 6 positions, iris diaphragm and filter holders. Working distance is 26 mm. Supplied with phase contrast annuli for 10x/20x, 40x and 60x objectives, brightfield position and slots for optional DIC prisms. Three filter holders allow the insertion of Ø 38 mm filters in the optical path. The arm with condenser can be tilted backwards for convenient access to the stage. This allows easy placement of large objects like flasks and Petri dishes

 

MAGNIFICATION CHANGER
A magnification changer with a 1.5x lens allows intermediary magnifications of 1.5 times the standard objective magnifications. For example switching from 20x to 30x or from 60x to 90x magnification can be done without the need to change objectives

FLUORESCENCE FILTER SET WHEEL
The Delphi-X Inverso is supplied with a 6-position fluorescence filter set wheel. See photo below. (More information on fluorescence on the Delphi-X Inverso fluorescence webpage)

FOCUS ADJUSTMENT
Coaxial 10 mm coarse and fine adjustments, 1 μm precision and with friction adjustment

ILLUMINATION
Transmitted 5 W LED or 100 W halogen Intensity adjustable with internal 100-240 V power supply. Fuse holder 5 A / 250 V. Delphi-X Inverso can be extended with fluorescence equipment

PACKAGE CONTENT
Supplied with metal insert for Ø 38 mm cell culture dish and a metal insert for Ø 54 mm cell culture dish with 76 x 26 mm slides, metal insert for Multiwell plates, metal insert  for Teraski plates, blue and green interference Ø 38 mm filters, power cord, dust cover, green filter and alignment telescope and user manual

ICSI SET
(Intracytoplasmic sperm injection)

  • Perfect for inexperienced users in need of training practice as well as for professionals
  • Complete manual system
  • Large movement range
  • Easy micropipette repositioning
  • Adjustable micropipette holder angle between 20° and 40°
  • Micropipette holder fixing knob reduces vibration and provides easy handling of the sperm
  • Easy installation and service
  • 3D Hydraulic manipulation joysticks for smooth movement
  • Pneumatic Air Injector for ICSI and holding
  • No service required for injector
  • Identical sensitive injectors on both sides and interchangeable
  • Top quality for affordable price
  • Medical device CE mark
  • Movement range: X/Y/Z: 20 mm each, 1 mm for one complete turn of the handle
  • Optional heating stage with controller

 

Set includes two 3D hydraulic joysticks, two pipette setup mechanisms, one connection bar with moving handle, two air injectors with tubing and pen type micromanipulation, pipette holder, two metal plates for injectors, one set of Allen wrenches, one ruler for mechanic home position adjustment. Unit is packed in a solid carry case

HEATING STAGES AE.8010 AND AE.8015
Heating glass stage for Euromex microscope stage with 110 mm circular hole. The glass plate fits the circular opening of the X-Y stage and enables a flat glass object-plate with constant temperature. The stage has an aluminum frame for superior resistance and flatness. Glass thickness 0.5 mm. Plate diameter 110 mm

Controller AE.8010

  • 2-Channel Temperature Controller with touchscreen interface
  • One controller can control up to two devices
  • On-board data logging allows for recording temperature as a function of time and logging
  • calibration events and alarms
  • The password protected controller is equipped with routines to re-calibrate the sensors
  • against certified thermometers
  • Temperature range: from ambient to 60°C
  • Temperature accuracy on specimen: ± 0.3°C
  • 4.3’’ touch screen interface
  • Alarm buzzer and external alarm connector
  • Self calibration routines enable high temperature accuracy

 

Controller AE.8015 
(photo: AE.8015 with heating stage)

This is the economic and compact single-channel Temperature Controller version of the AE.8010. This model combines performance and simplicity at a economic price

  • Single channel Temperature controller with LCD display temperature control push buttons.
  • Small and robust while maintaining reliability
  • Straight forward in usage
  • Temperature range: from ambient to 60°C
  • Set point Resolution: 0.1°C
  • One-Point Temperature Calibration and Adjustment

Filters in sliders

 

 


 

Downloads

   Delphi-X_Inverso_product_datasheet_Engish

https://www.euromex.com/en/products/products/fluorescence-microscopes/university-fluorescence-microscopes/delphi-x-inverso/